Indoor Modular Data Center
A factory-integrated micro module that brings racks, cold-plate liquid cooling with CDU, power distribution, monitoring and management, lightning protection and grounding, structured cabling and fire protection into one enclosed dual-row footprint, configured to your rack count, kW per rack and cooling capacity.

The Liquid-Cooled Data Center Micro Module is an indoor modular data center built around a dual-row enclosed aisle. Server heat is removed through cold plates and a CDU secondary loop, while seven systems are integrated into the delivered module: racks, power distribution, thermal management, monitoring and management, lightning protection and grounding, structured cabling, and fire protection.
Rack count, power per rack, cooling capacity, aisle dimensions and redundancy are defined per project, so the module is specified around your IT load rather than adjusted afterwards.
Heat is captured at the server by cold plates and rejected through a CDU secondary loop. Matched equipment can include a plate heat exchanger, dry cooler or cooling tower, pumps, power distribution, monitoring and fire protection.
Rack rows are arranged in a dual-row enclosed aisle layout, with aisle dimensions set for each project.
Racks, power distribution, thermal management, monitoring and management, lightning protection and grounding, structured cabling and fire protection are integrated before delivery.
Multi-unit group control and automatic switchover are available as project-configured functions. The XINKE SMART system supports equipment monitoring, operating management and abnormal-condition alerts.
The cabinet frame is Q235B carbon steel with black powder coating; coolant piping and manifolds are SS304 stainless steel.
Factory integration reduces on-site installation work and supports phased infrastructure deployment. Services cover solution design, equipment integration, commissioning and operations support.
| Deployment | Indoor |
|---|---|
| Rack layout | Dual-row enclosed aisle |
| Cooling method | Cold-plate liquid cooling with CDU |
| Integrated systems | 7 |
| System scope | Racks, power distribution, thermal management, monitoring and management, lightning protection and grounding, structured cabling, fire protection |
| Control functions | Multi-unit group control, automatic switchover (project-configured) |
| Rack count | Project-specific |
| Power per rack | Project-specific (kW) |
| Cooling capacity | Project-specific (kW) |
| Aisle dimensions | Project-specific (mm) |
| Redundancy | Project-specific |
| Cabinet frame | Q235B carbon steel, black powder coating |
| Coolant piping and manifolds | SS304 stainless steel |
The model is not fixed at catalogue level: configuration is project-specific and the model is confirmed after configuration approval. The technical agreement carries the final designation together with rack count, power per rack, cooling capacity, aisle dimensions and redundancy. Cooling-side equipment is selected with the module and can include a CDU, plate heat exchanger, dry cooler or cooling tower, pumps, power distribution, monitoring and fire protection systems.
The cabinet frame is fabricated from Q235B carbon steel with a black powder coating. Coolant piping and manifolds are SS304 stainless steel, giving the wetted loop a single defined material specification. The module is assembled from racks, power distribution, thermal management, monitoring, grounding, cabling and fire-protection elements into one dual-row enclosed aisle structure.
Manufacturing site certifications: ISO 9001:2015 (cert. 06724Q20082R0S), ISO 14001:2015 (cert. 06726E00031R001), and CCS Works Approval for equipment containers HE24S1019 (model XKKJ-40HC003, ISO code 45SM, valid to 2029-12-30, subject to annual CCS surveillance). Certification scope for a specific order is defined in the project technical agreement.
Configuration is set per project through the technical agreement, including rack count, kW per rack, cooling capacity, aisle dimensions and redundancy. Before design, site conditions are confirmed: ambient dry-bulb and wet-bulb temperatures, altitude, water quality and IT load, plus freeze protection, condensation prevention, corrosion protection, noise, electrical supply and local certification requirements. Delivery scope spans requirements assessment, solution design, factory prefabrication, integrated commissioning, factory testing, transport, deployment and operations support.
An ASIC modular computing center in Uzbekistan is presented in the 10 September 2026 corporate presentation (page 5) with an aerial site photograph, as an example of overseas modular computing-center deployment. The presentation does not disclose capacity, customer name, operating duration or measured efficiency results.
Configuration is project-specific. The model is confirmed after configuration approval and recorded in the technical agreement.
Yes. Rack count, power per rack, cooling capacity, aisle dimensions and redundancy are project-specific values defined in the technical agreement.
Cold-plate liquid cooling with a CDU secondary loop. Matched equipment can include a plate heat exchanger, dry cooler or cooling tower, pumps, power distribution, monitoring and fire protection.
No. Deployment for this configuration is indoor, following a dual-row enclosed aisle layout.
Ambient dry-bulb and wet-bulb temperatures, altitude, water quality and IT load, together with freeze protection, condensation prevention, corrosion protection, noise, electrical supply and local certification requirements.
Services span requirements assessment, solution design, factory prefabrication, integrated commissioning, factory testing, transport, deployment and operations support.
Configuration, delivery schedules and certification scope are defined by each project technical agreement, based on the approved configuration and destination requirements.
Send your rack count, kW per rack, cooling capacity target, site conditions and destination certification requirements to receive a configured proposal.