High-Power Secondary Loop
The XK-BGCDU high-power CDU series provides 240, 600, 1,200 and 2,500 kW capacity options for AI data centers, HPC and integrated liquid-cooling infrastructure. It connects primary cooling to the secondary loop through heat exchange and circulation control.

Four capacity steps for large liquid-cooling loads
The XK-BGCDU series connects primary cooling infrastructure to the secondary loop through heat exchange and circulation control. It is intended for AI data centers, high-performance computing and integrated liquid-cooling infrastructure. Intelligent controls support operating-status monitoring, and the unit integrates with cold plates, piping and monitoring systems. Pump redundancy is project-specific. Flow rate, differential pressure and supply/return temperature are model-specific and confirmed for the selected model and site conditions.
Facts tied to the XK-BGCDU series
Catalog specifications and model-specific operating conditions
| Parameter | XK-BGCDU Series |
|---|---|
| Models | XK-BGCDU-240 / 600 / 1200 / 2500 |
| Cooling capacity | 240 / 600 / 1,200 / 2,500 kW |
| Installation | Project-specific; range options include rack-mounted, sidecar and in-row |
| Flow rate | Model-specific (m³/h) |
| Differential pressure | Model-specific (kPa) |
| Supply / return temperature | Model-specific (°C) |
| Coolant compatibility | Confirmed per project |
| Pump redundancy | Project-specific |
| Heat exchanger / internal piping | Stainless steel on applicable models; confirm grade and wetted materials |
| Controls | Intelligent operating-status monitoring |
| Integration | Cold plates, piping and monitoring systems |
| Rating basis | Catalog specifications; model-specific operating conditions |
Select capacity by AI or HPC block load
| Model | Cooling capacity | Series |
|---|---|---|
| XK-BGCDU-240 | 240 kW | XK-BGCDU high-power CDU |
| XK-BGCDU-600 | 600 kW | XK-BGCDU high-power CDU |
| XK-BGCDU-1200 | 1,200 kW | XK-BGCDU high-power CDU |
| XK-BGCDU-2500 | 2,500 kW | XK-BGCDU high-power CDU |
Wetted-path confirmation is project-specific
Plate heat exchanger and internal piping are stainless steel on applicable models. Confirm exact grade and wetted materials for the selected model and coolant. The high-power CDU groups heat exchange, circulation and control functions for the project layout. Pump redundancy is project-specific. For site integration, confirm freeze protection, condensation prevention, corrosion protection, noise, electrical supply and local certification requirements.
Large AI, HPC and integrated liquid-cooling deployments
High-power secondary-loop cooling for dense AI halls.
Cold-plate cooling for high-performance computing clusters.
Connects primary cooling to direct-to-chip secondary loops.
Fits integrated liquid-cooling infrastructure and phased builds.
Project-defined configuration
Procurement and engineering questions
XK-BGCDU-240, 600, 1200 and 2500 cover 240 kW, 600 kW, 1,200 kW and 2,500 kW. Selection depends on IT load, supply and return temperatures, redundancy target and site conditions.
The CDU range includes rack-mounted, sidecar and in-row options. The final XK-BGCDU layout is confirmed with engineering for each project.
Flow rate and differential pressure are model-specific and confirmed against the selected model, IT load and project operating conditions.
Coolant compatibility is confirmed per project. Wetted materials are checked against the selected model and coolant.
Yes. Pump redundancy is project-specific and configured to match the availability requirement.
Intelligent controls support operating-status monitoring and integration with monitoring systems.
The manufacturing site holds ISO 9001:2015 and ISO 14001:2015 certificates. The certified scope covers R&D and production of cloud computing liquid cooling equipment and controls. Project-specific certification scope is confirmed separately.
Provide IT load, supply and return temperatures, flow and pressure requirements, coolant, redundancy target, installation layout and site conditions.
Send project requirements to the Xinke Intelligent Technology team for high-power CDU selection and configuration review.
Use product, model and angle in filenames
Main image filename: cdu-xk-bgcdu-high-power-unit.png
Alt text: High-power CDU XK-BGCDU series unit for AI data center cooling
Detail image filename: cdu-xk-bgcdu-1200-high-power-connections.png
Alt text: XK-BGCDU-1200 high-power CDU piping connection side